Integrated Turn-Key Test System for Redox Flow Cell Research & Development
✓ Charge / Discharge Cycling & Performance Characterization
✓ Custom FlowCell™ Software for Complete Process Control & Experimentation
✓ Multi-Range Potentiostat for High Accuracy
✓ Whole and Half-Cell Voltage, EIS and HFR Measurement
✓ Real-Time State-of-Charge Monitoring
Features:
- Integrated system including: cell charge and discharge, electrolyte flow control, temperature control, and data acquisition
- FlowCell™ software for user-friendly system operation & experimentation
- High-current, multi-range potentiostat operates in current- or voltage-controlled operation
- Impedance Analyzer for EIS and HFR measurements during charge, discharge and at OCV
- High-impedance V-sense inputs for whole and half-cell measurements including EIS & HFR
- State-of-charge (SOC) voltage inputs for DC SOC measurement when used with SOC cell
- All non-metallic electrolyte handling system: 2 pumps, electrolyte reservoirs, drain and purge valves
- Cell and electrolyte temperature control up to 50oC
- High performance peristaltic pumps with variable flow control including forward and reverse flow
- Electrolyte shielding with inert gas purge and blanket
- Single USB communications interface

Specifications:
Potentiostat:
Current Ranges (3): 7 A, 700 mA, 70 mA full scale (FS)
Current Resolution: 488 µA (7 A FS) to 4.88 µA (70 mA FS)
Current Accuracy: ± 0.3% of full scale current of selected range
Voltage Measurement and Data Acquisition:
Set and Read Voltage vs. WE: ± 3.000 V
Cell Voltage Sense Leads: Differential with driven shields
Voltage Measurement Resolution: 152 µV
Sense Lead Input Resistance: 1 GΩ
Data Acquisition Rate: 10 points/second
Impedance Analyzer:
Internal Impedance Analyzer Type: Single sine, one generator and two gain/phase measurement channels
Internal Analyzer Frequency Range: 1 mHz to 10 kHz
Electrolyte Fluid Handling System: Computer-controlled peristaltic pumps (2); <1 to 1,000 mL/min
All non-metallic flow path and reservoirs
Independent drain & purge valves for positive & negative electrolytes
Nitrogen purge and blanket; Electrolyte level monitoring
Optional Data Acquisition: 8 Temperature and 8 Voltage measurement channels
Temperature Controllers:
Three: cell, anode electrolyte, cathode electrolyte
Set & Report Accuracy: ±0.25% of span, ±1 least significant digit
Sensor Type: Thermocouple, Type T
Environment:
Operating Temperature: 5 to 35 °C
Power Source: 110-120 V, 50-60 Hz, 10 A (Export model 220-240V, 50-60 Hz, 5 A)
Size and Weight: Electronic Control Unit: 48 W x 13 H x 53 D cm3 (19 x 5.25 x 21 in3); 9 kg (20 lb)
Fluid Control Unit: 50 W x 65 H x 65 D cm3 (20 x 25 x 25 in3); 16 kg (35 lb)
Safety Features:
Automatic shutdown on under- and over-voltage or current, over-temperature, or communications failure
Emergency stop switch for manual operator shutdown
Download the FlowCell™ software (version 1.1b, released 12/5/2012)
*Specifications for 25oC ambient temperature unless otherwise noted.