Text Size

892 Data Acquisition Expansion system

Data acquisition accessories for the 890C - Model 892 multichannel data collection system for up to 16 additional channels of voltage and/or temperature measurement with 890C series loads. The 892 is ideal for inlet/outlet pressure sensors, inlet/outlet cooling, or distributed stack temperatures, among others. Call for details and options.

The Model 892 Data Expansion Subsystem is a hardware component intended to increase the input capabilities of the Series 890C family of fuel cell test systems. The model 892 is configured with two factory-installed eight-channel data acquisition modules, each of which is factory-configured for one of several input types.



  • Remote operation from RS-485 interface with an 890C or host computer direct using RS-232/485 converter
  • 16 thermocouple inputs with cold junction compensation, or 16 Voltage or Current inputs, or 8 voltage or current inputs and 8 thermocouple inputs
  • 2U 19" rack-mount enclosure
  • Supported by FuelCell® software directly or through an external program

Specifications:

  • Number of Channels: 16 (differential)
  • Supports thermocouple types: J (-210 to 760°C)
    • K (-270 to 1372°C)
    • T (-270 to 400°C)
    • E (-270 to 1000°C)
    • R (0 to 1768°C)
    • S (0 to 1768°C)
    • B (0 to 1820°C)
    • C (0 to 2320°C)
  • Input Voltage Ranges: ±15mV, ±50mV, ±100mV, ±150mV, ±500mV, ±1V, ±2.5V, ±5V, ±10V
  • Voltage Accuracy: ±0.1% of full-scale
  • Input Current Range: ±20mA (using 125 ohm 0.1% resistor)
  • Current Accuracy: ±0.1% of full-scale
  • Voltage, Current Resolution: 0.01 % of full scale
  • AC Noise Rejection (50/60Hz): Common Mode: 120VAC
  • Input Overvoltage Protection: ±35V
  • Input Impedance (differential): 2x10^7 ohms or greater
  • Maximum Voltage Difference on +/-10V for +/-5V, +/-10V ranges, an 8-Channel Group: +/-2.5V for other ranges
  • Temperature Accuracy: ±0.5°C at 0°C
  • Temperature Resolution: 0.01°C
  • Power Requirement: 100-240V 50/60Hz, 0.1A (total for system; 2 modules)
  • Operating Temperature: 0-40 oC
  • Physical Dimensions: 2U (3.5 inch) height, 19" rack-mount width, 8" depth

 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Scribner Associates Inc.

150 E. Connecticut Avenue
Southern Pines, NC 28387
Phone: 910-695-8884
Fax: 910-695-8886
Email: info@scribner.com

Site Design By:

Tech-SenseTech-Sense