Dr. Kevin R. Cooper, Principal Scientist, Scribner Associates Incorporated
Introduction
The article introduces the use of cyclic voltammetry (CV) for evaluation of catalyst utilization and electrochemical surface area of fuel cell electrocatalysts.
A typical proton exchange membrane fuel cell (PEMFC) catalyst layer is a porous, three dimensional structure consisting of carbon support, platinum (Pt) or Pt-alloy catalyst and ionomer such as Nafion®, all in intimate contact. The carbon support enhances the bulk electronic conductivity of the electrode and dispersion of the catalyst nanoparticles. The ionomer serves to bind the electrode layer and facilitate proton conduction to the reaction site. Voids allow for mass transport of gas or liquid phase reactants and products to and from the carbon-supported electrocatalyst. The electrochemical activity (current/nominal area) of the catalyst layer is a function of the extent and quality of the three phase boundaries where reactants, ionically and electrically conducting material and active catalyst sites are in intimate contact. Electrochemical surface area and catalyst utilization are critical performance metrics for catalyst and membrane electrode assembly (MEA) developers and manufacturers.
The technique for determining the electrochemical surface area (ECSA) of fuel cell electrodes by CV analysis has been used for several decades. The procedure involves cycling the electrode of interest over a voltage range where charge transfer reactions are adsorption-limited at the activation sites. That is, the electrode potential is such that the number of reactive surface sites can be obtained by recording the total charge required for monolayer adsorption/desorption.
Common reactions used when characterizing PEMFC electrodes are the hydrogen adsorption/desorption (HAD)1,

or the oxidative stripping of adsorbed carbon monoxide2,

Figure 1 shows a typical CV voltammogram of the HAD reaction. The process of interest is the electroreduction of protons and adsorption of hydrogen on the catalyst surface, that is, reaction [1] in the reverse direction. The hydrogen adsorption charge density (qPt in Coulombs/cm2) due to this reaction determined from the CV experiment is used to calculate the ECSA of the fuel cell electrode.

Figure 1. Cyclic voltammogram of PEM fuel cell catalyst layer for ECSA analysis by hydrogen adsorption/desorption. Conditions: Scan rate = 40 mV/s; Cell: 35 °C; 100% RH anode/cathode; 1 atm.
The electrochemical surface area (ECSA) of the Pt catalyst is calculated from the charge density qPt (C/cm2electrode) obtained from the CV experiment; the charge required to reduce a monolayer of protons on Pt, Gamma = 210 µC/cm2Pt 1,3; and the Pt content or loading in the electrode, L in gPt/cm2electrode,

Not all of the catalyst used to make the fuel cell electrode is accessible to reactants (e.g., protons and oxygen at the cathode) and/or is in electrically contact and thus is not able to participate in the electrochemical reaction. The fraction of the catalyst that is available to participate in electrode reactions is given by the ratio of ECSA to the specific area of the catalyst obtained by the catalyst manufacturer using chemisorption or other ex situ techniques (also in cm2Pt / gPt). This ratio is referred to as utilization. Higher catalyst utilization is better.
Utilization is an idealized condition because the very low reaction rate used during the ECSA measurement results in negligible transport limitations. In a fuel cell operating at a practical current density, oxygen and/or proton transport resistances could decrease the amount of catalyst that participates in the cathode reaction4, effectively decreasing utilization.
Fuel cell electrodes may be examined for their electrocatalytic performance by ex situ or in situ voltammetry experiments. In the case of ex situ experiments, also known as half-cell experiments, the properties of the electrode are evaluated using a standard three-electrode cell where an aqueous solution (e.g., perchloric acid) simulates the proton-conducting electrolyte in a PEMFC. Half-cell experiments are a convenient and relatively fast method of screening electrocatalysts but are not suitable for evaluation of fuel cell electrodes under operating conditions.
In Situ ECSA and Catalyst Utilization Measurement
In situ experiments use a two-electrode configuration in which one of the electrodes of the fuel cell serves as both a counter electrode and a pseudo-reference electrode. Typically, the electrochemical activity of the fuel cell cathode is of most interest because of the sluggish kinetics of the oxygen reduction reaction. Therefore, the cathode is often chosen to be the working electrode (WE). The fuel cell anode is used as the CE/RE with the inherent assumption that polarization of this electrode is small relative to the polarization imposed on the fuel cell cathode, the working electrode. The current densities obtained in the ECSA tests are relatively small and justify this assumption.
The test conditions for in situ ECSA evaluation by CV are akin to those used for fuel cell crossover evaluation presented in a the Aug/Sept 2008 issue of Fuel Cell5. The fuel cell electrode of interest (the WE) is filled with water or slowly purged with a non-reactive gas such as nitrogen, while hydrogen is fed to the other electrode (the CE/RE). See additional comments on the effect of inert gas purge rates below.
The potential of the working electrode is swept at about 20 to 50 mV/s first in the anodic direction to oxidize the adsorbed hydrogen Hads to H+ and then in the cathodic direction to electrochemically reduce the H+ back to Hads. Alternating anodic and cathodic currents occur at the electrode. Note that a fuel cell is a driving system whereas the ECSA measurement is a driven system requiring the use of a potentiostat or other controllable power supply.
Results of the CV scan are presented as a voltammogram of current density vs. the working electrode potential (Figure 2). The voltammogram exhibits multiple peaks associated with both the oxidation and reduction reactions. Each peak is indicative of the adsorption onto or desorption from a particular crystal index of platinum, e.g., 100 and 110 indices1.
Integration of the hydrogen desorption/adsorption peaks that result as a consequence of the forward and reverse scans, respectively, is used to estimate the electrochemically active surface area of the electrocatalyst. The shaded area in Figure 2 represents the charge density qPt arising from hydrogen adsorption on the Pt catalyst during the reverse sweep.
The baseline current at potentials between 0.4 and 0.6 V is the sum of the capacitive current due to charging/discharging of the electrical double layer (positive on the forward scan and negative on the reverse scan) and the transport limited H2 crossover current. Non-faradaic or capacitive current arises due to charging/discharging the electrical double layer capacitance of electrode/electrolyte interface. This current involves charge accumulation but not chemical reactions or charge transfer. This current is directly proportional to the scan rate, v (V/s),

where Cdl is the specific capacitance of the electrode double layer (Farad/cm2electrode). The electrical charge associated with double layer charging and fuel crossover must be accounted for in the analysis to avoid overestimating the charge attributed to the electrocatalytic activity.
Note that the capacitance of the electrode Cdl can be determined from the double layer charging current density idl and Eq. (2). Both the platinum and carbon support contribute to the electrode’s capacitance,

where C*dl,Pt and C*dl,carbon are the specific double layer capacitance (in F/cm2) for Pt and carbon, respectively, and APt and Acarbon are the area of platinum and carbon in the electrode (cm2/cm2electrode), respectively. The specific double layer capacitance for platinum was reported to be 40 µF/cm2Pt 6 and for Vulcan XC-72, a common catalyst support material, the value was ~ 8 µF/cm2carbon 7.
The specific area of platinum APt is determined from the previously determined ECSA and the catalyst loading,

From this, the specific area of the carbon catalyst support can be obtained using Eq. (3).
Thus, properties of the catalyst support within the fuel cell electrode can be also be determined from in situ CV measurements of the electrochemical surface area of the fuel cell electrodes.

Figure 2. Cyclic voltammogram of a PEMFC catalyst layer highlighting the region of interest. The shaded area is the charge density due to H adsorption during the reverse scan and is used in the ECSA calculation. Conditions as in Figure 1.
Notes and caveats on hydrogen adsorption for fuel cell electrode catalyst evaluation:
• Both relative humidity (RH) of the gases to which the electrode is exposed, and the electrode temperature influence the observed ECSA. Fully-saturated or super-saturated (>=100% RH) conditions are generally used.
• The flow rate of nitrogen or other inert gas at the working electrode can significantly influence the shape of the adsorption/desorption curve and calculated ECSA8. The artifact was attributed to the rate of mass transfer of H2 away from the working electrode during the voltage scan. With increasing N2 purge rate, H2 is more readily swept from the electrode surface, decreasing the partial pressure of H2 at the electrode thereby increasing the Nernst potential for hydrogen evolution. All else being equal, conditions that decrease the concentration of H2 at the WE increase the reversible potential for hydrogen evolution. As the potential at which hydrogen evolution begins to occur during the reverse scan increases, the more difficult it is to accurately quantify the hydrogen adsorption from the voltammogram. Low purge gas flow rate ~ 1 sccm/cm2 of active area may be preferred.
• Hydrogen adsorption is very suitable for electrocatalysts where the HAD is well defined and not disturbed by other faradaic processes, e.g., Pt, Ir, Rh
• The HADS method is not suitable for metals such as Ruthenium which exhibit oxygen adsorption-desorption at potentials inside the hydrogen adsorption-desorption region; the contributions can not be separated.
• The HADS method is not suitable for metals, such as Palladium, that absorb H, thus confounding determination of the hydrogen monolayer concentration. Alternative methods such as CO adsorption technique should be used.
Electrochemical surface area experiments are an important diagnostic for fuel cell catalyst, electrode and membrane electrode assembly (MEA) developers and manufacturers. The ECSA should be determined when a new MEA and fuel cell is fabricated as well as periodically during testing as a diagnostic for fuel cell electrode degradation. The experiment should be conducted on membrane electrode assemblies that have been through a break-in procedure to fully active the electrode. Finally, ECSA measurements are used in RDE studies to ensure that catalyst has not fallen off during the RDE experiments.
Acknowledgement – The author is grateful for the comments and suggestions provided by Vijay K. Ramani, Assistant Professor, Chemical Engineering, Illinois Institute of Technology.
References
1. K. Kinoshita and P. Stonehart, “Preparation and Characterization of Highly Dispersed Electrocatalytic Materials” in Modern Aspects of Electrochemistry, Vol. 12, Chapter 4, J.O.M. Bockris and B.E. Conway, Eds., Plenum Press: New York, 183-266 (1977).
2. T.R. Ralph, G.A. Hards, J.E. Keating, S.A. Campbell, D.P. Wilkinson, M. Davis, J. St-Pierre and M.C. Johnson, “Low Cost Electrodes for Proton Exchange Membrane Fuel Cells – Performance in Single Cells and Ballard Stacks,” Journal of the Electrochemical Society, 144, 3845-3857 (1997).
3. F. Gloaguen, J.-M. Leger and C. Lamy, “Electrocatalytic Oxidation of Methanol on Platinum Nanoparticles Electrodeposited onto Porous Carbon Substrates,” Journal of Applied Electrochemistry, 27, 1052 (1997).
4. K.C. Neyerlin, W. Gu, J. Jorne, J.A. Clark and H.A. Gasteiger, “Cathode Catalyst Utilization for the ORR in a PEMFC,” Journal of the Electrochemical Society, 154, B279-B287 (2007).
5. K.R. Cooper, “In Situ PEM Fuel Cell Fuel Crossover and Electrical Short Circuit Measurement,” Fuel Cell Magazine, Aug/Sept, 34-35 (2008).
6. A. Parthasarathy, B. Dave, S. Srinivasan, J.A. Appleby and C.R. Martin, “The Platinum Microelectrode/Nafion Interface: An Electrochemical Impedance Spectroscopic Analysis of Oxygen Reduction Kinetics and Nafion Characteristics,” Journal of the Electrochemical Society, 139, 1634-1641 (1992).
7. K.H. Kangasniemi, D.A. Condit and T.D. Jarvi, “Characterization of Vulcan Electrochemically Oxidized under Simulated PEM Fuel Cell Conditions,” Journal of the Electrochemical Society, 151, E125-E132 (2004).
8. R.N. Carter, S.S. Kocha, F.T. Wagner, M. Fay and H.A. Gasteiger, “Artifacts in Measuring Electrode Catalyst Area of Fuel Cells through Cyclic Voltammetry,” ECS Transactions, 11(1), 403-410 (2007).